Constructions
1-Conductor | Solid copper (Class 1) |
2-Insulation | Polyvinyl chloride (PVC) |
3-Filler | Polyvinyl chloride (PVC) |
5-Armour | Galvanized round steel wire (GSWA) |
6-Outer sheath | Polyvinyl chloride (PVC) |
1-Conductor | Solid copper (Class 1) |
2-Insulation | Polyvinyl chloride (PVC) |
3-Filler | Polyvinyl chloride (PVC) |
5-Armour | Galvanized round steel wire (GSWA) |
6-Outer sheath | Polyvinyl chloride (PVC) |
Min. bending radius | 12 x D |
Max. operating temperature | 70° |
Max. short circuit temperature | 160° |
Rated voltage Uo/U | 0.6/1 kV |
AC test voltage | 3,5 kV |
Flame propagation test on single cable | EN 60332-1 |
Lead free | Pb |
Nomial Cross Section mm² | Overall Diameter mm Approximately | Net Weight kg/km Approximately | Conductor DC Resistance at (20°C) max. ohm/km | Current Carrying Capacity in |
Air (A) | ||||
TRAFFIC SIGNAL (0,6/1 kV) | ||||
8×1 | 13,2 | 392 | 18,1 | 12 |
8×1,5 | 13,9 | 445 | 12,1 | 18 |
12×1 | 16,2 | 620 | 18,1 | 12 |
12×1,5 | 17,4 | 734 | 12,1 | 18 |
16×1 | 18,0 | 748 | 18,1 | 12 |
16×1,5 | 19,3 | 888 | 12,1 | 18 |
20×1 | 20,1 | 917 | 18,1 | 12 |
20×1,5 | 20,6 | 1021 | 12,1 | 18 |
To be used in traffic signalling systems.