Constructions
| 1-Conductor | Solid copper (Class 1) |
| 2-Insulation | Polyvinyl chloride (PVC) |
| 3-Filler | Polyvinyl chloride (PVC) |
| 4-Outer sheath | Polyvinyl chloride (PVC) |
| 1-Conductor | Solid copper (Class 1) |
| 2-Insulation | Polyvinyl chloride (PVC) |
| 3-Filler | Polyvinyl chloride (PVC) |
| 4-Outer sheath | Polyvinyl chloride (PVC) |
| Min. bending radius | 12 x D |
| Max. operating temperature | 70° |
| Max. short circuit temperature | 160° |
| Rated voltage Uo/U | 0.6/1 kV |
| AC test voltage | 3,5 kV |
| Flame propagation test on single cable | EN 60332-1 |
| Lead free | Pb |
| Nomial Cross Section mm² | Overall Diameter mm Approximately | Net Weight kg/km Approximately | Conductor DC Resistance at (20°C) max. ohm/km | Current Carrying Capacity in |
| Air (A) | ||||
| TRAFFIC SIGNAL (0,6/1 kV) | ||||
| 8×1 | 11,4 | 227 | 18,1 | 12 |
| 12×1 | 13,7 | 333 | 18,1 | 12 |
| 8×1+6 | 13,2 | 342 | 18,1/3,08 | 12 |
| 12×1+6 | 15,3 | 454 | 18,1/3,08 | 12 |
To be used in traffic signalling systems