5 kV & 2/3 kV AIRFIELD CABLE (TAPE)

Constructions

1-Conductor Stranded copper (Class 2)
2-Insulation Cross linkable polyethylene (XLPE)
3-Filler Copper or brass tape (TAPE)
4-Outer sheath Polyvinyl chloride / Polyethylene (PVC/PE)

Specifications

Min. bending radius 20 x D
Max. operating temperature 90°
Max. short circuit temperature 250°
Rated voltage Uo/U 2/3 kV – 5 kV
AC spark test voltage 12 kV – 18 kv
Lead free Pb

Technical Data

Cross Sectional Area mm² Voltage Rating (kV) Screen Tape Thickness mm Outer Sheath Overall Diameter mm approximately Approximately Total Weight kg/km
AIRFIELD CABLE (5 kV-2/3 kV)
 1X6 5 kV Copper Tape  0,10  PVC  12,9  215
 1X6 5 kV  Brass Tape  0,11  PVC  12,9  209
 1X6 2/3 kV  Copper Tape  0,10  PVC  12,1 165
 1X6 2/3 kV  Brass Tape  0,11  PVC  12,1 156
 1X6 2/3 kV  Copper Tape  0,10  PE  12,1 175
 1X6 2/3 kV  Brass Tape  0,11  PE  12,1 170
 1X6 2/3 kV  Copper Tape  0,10  XLPE  9,95 165
1X6 2/3 kV Brass Tape 0,11 XLPE 9,95 158
8 AWG 5 kV Brass Tape 0,11 PVC 12,1 228
8 AWG 5 kV  Copper Tape  0,10 PVC 12,1 235

Applications

These special cables are used in airfield lighting and signalling. Primary cables for the serie circuit connetting the constant current regulators and the isolating transformers, and between the isolating transformers.

Standards