PVC/SWA

Constructions

1-Conductor Solid copper (Class 1)
2-Insulation Polyvinyl chloride (PVC)
3-Filler Polyvinyl chloride (PVC)
5-Armour Galvanized round steel wire (GSWA)
6-Outer sheath Polyvinyl chloride (PVC)

Specifications

Min. bending radius 12 x D
Max. operating temperature 70°
Max. short circuit temperature 160°
Rated voltage Uo/U 0.6/1 kV
AC test voltage 3,5 kV
Flame propagation test on single cable EN 60332-1
Lead free Pb

Technical Data

Nomial Cross Section mm² Overall Diameter mm Approximately Net Weight kg/km Approximately Conductor DC Resistance at (20°C) max. ohm/km Current Carrying Capacity in
Air (A)
TRAFFIC SIGNAL (0,6/1 kV)
8×1 13,2 392 18,1 12
8×1,5  13,9 445 12,1 18
12×1 16,2 620 18,1 12
12×1,5 17,4 734 12,1 18
16×1 18,0 748 18,1 12
16×1,5 19,3 888 12,1 18
20×1 20,1 917 18,1 12
20×1,5 20,6 1021 12,1 18

Applications

To be used in traffic signalling systems.

Standards