AluminiumAluminium АПвВГ, АПвБШв

Power cables with aluminium conductors and XLPE insulation, 0.66 and 1 kV

ГОСТ 31996-2012

  • Аaluminium conductor
  • ПвXLPE insulation
  • Бsteel tape armour
Request a quote
Aluminium АПвВГ, АПвБШв
continuous on the conductor
+90 °Ccontinuous on the conductor
conductor cross-section
2,5–240 mm²conductor cross-section
number of cores
1–5number of cores
conductor
aluminiumconductor
service life
30 yearsservice life

Types and versions · 18

BasicXLPE
  • АПвВГ
  • АПвБШв
  • АПвБбШв

Aluminium conductors, XLPE insulation; АПвВГ with PVC sheath, АПвБШв with steel tape armour, АПвБбШв with profiled tape armour

нг(А)flame retardant
  • АПвВГнг(А)
  • АПвБШвнг(А)
  • АПвБбШвнг(А)

Flame retardant in group installation (category A)

нг(А)-LSlow smoke
  • АПвВГнг(А)-LS
  • АПвБШвнг(А)-LS
  • АПвБбШвнг(А)-LS

Reduced fire hazard, low smoke and gas emission

нг(А)-LSLTxlow toxicity
  • АПвВГнг(А)-LSLTx
  • АПвБШвнг(А)-LSLTx
  • АПвБбШвнг(А)-LSLTx

The same, low toxicity of combustion products

нг(А)-FRLSfire-resistant
  • АПвВГнг(А)-FRLS
  • АПвБШвнг(А)-FRLS
  • АПвБбШвнг(А)-FRLS

Fire-resistant, with a thermal barrier of mica tapes

нг(А)-FRLSLTxfire-res., low tox.
  • АПвВГнг(А)-FRLSLTx
  • АПвБШвнг(А)-FRLSLTx
  • АПвБбШвнг(А)-FRLSLTx

Fire-resistant, low toxicity of combustion products

Construction

1234
Schematic cross-section. Core and sheath colours may differ.
  1. Conductoraluminium, class 1 or 2 to GOST 22483
  2. InsulationXLPE; FR: over mica tapes
  3. Armoursteel tapes (Б) or profiled tape (Бб)
  4. Sheath / outer sheathPVC compound; нг(А), LS: reduced fire hazard

Applications

  • Distribution networks and high-power loads: XLPE carries a higher load, while the aluminium conductor reduces line weight and cost.
  • АПвВГ indoors and in cable structures; АПвБШв, АПвБбШв in the ground; нг(А), LS, FRLS for group installation.
XLPE and aluminium: an economical solution for heavily loaded distribution networks.

Technical data

Voltage0.66 kV; 1 kV (50 Hz)
Operation−50…+50 °C
Installation without preheatingnot below −15 °C
Bending radius10 D single-core; 7.5 D multi-core
Conductor temperature+90 / +130 / +250 °C *
Test voltage3.5 kV (1 kV)
Service life / warranty30 years / 5 years

* conductor temperature: continuous / overload / short circuit

Conductor cross-sections

1–5×2,5–240

number of cores × cross-section, mm²

How to write the order

Кабель АПвБШв 4×50ок(N)-1 ГОСТ 31996-2012

АПвБШв, 4 aluminium conductors of 50 mm², solid round, with neutral conductor, 1 kV

Aluminium АПвВГ, АПвБШв

Types: 18 · 2,5–240 mm²