Skip to content
HARMONY
CABLE

XLPEXLPE-insulated

Power cables with copper conductors and XLPE insulation ПвВГ, ПвБШв, ПвБбШв, 0.66 and 1 kV

ГОСТ 31996-2012 СТ РК IЕС 60502-1-2012

  • ПвXLPE insulation
  • Бsteel tape armour
  • ШвPVC outer sheath
Request a quote
XLPE-insulated
continuous on the conductor
+90 °Ccontinuous on the conductor
conductor cross-section
1,5–400 mm²conductor cross-section
number of cores
1–5number of cores
in short circuit
+250 °Cin short circuit
service life
30 yearsservice life

Types and versions · 17

BasicXLPE
  • ПвВГ
  • ПвБШв
  • ПвБбШв

XLPE insulation; ПвВГ with PVC sheath, ПвБШв with steel tape armour, ПвБбШв with profiled tape armour, PVC outer sheath

нг(А)flame retardant
  • ПвВГнг(А)
  • ПвБШвнг(А)
  • ПвБбШвнг(А)

Flame retardant in group installation (category A)

нг(А)-LSlow smoke
  • ПвВГнг(А)-LS
  • ПвБШвнг(А)-LS
  • ПвБбШвнг(А)-LS

Reduced fire hazard, low smoke and gas emission

нг(А)-LSLTxlow toxicity
  • ПвВГнг(А)-LSLTx
  • ПвБШвнг(А)-LSLTx
  • ПвБбШвнг(А)-LSLTx

The same, low toxicity of combustion products

нг(А)-FRLSfire-resistant
  • ПвВГнг(А)-FRLS
  • ПвБШвнг(А)-FRLS

Fire-resistant, with a thermal barrier of mica tapes

нг(А)-FRLSLTxfire-res., low tox.
  • ПвВГнг(А)-FRLSLTx
  • ПвБШвнг(А)-FRLSLTx
  • ПвБбШвнг(А)-FRLSLTx

Fire-resistant, low toxicity of combustion products

Construction

1234
Schematic cross-section. Core and sheath colours may differ.
  1. Conductorcopper, class 1 or 2 to GOST 22483
  2. InsulationXLPE; FR: over mica tapes
  3. Armoursteel tapes (Б) or profiled tape (Бб)
  4. Sheath / outer sheathPVC compound; нг(А), LS: reduced fire hazard

Applications

  • XLPE carries a higher current load and overloads than PVC: for distribution networks and high-power loads.
  • ПвВГ indoors and in cable structures; ПвБШв, ПвБбШв in the ground (trenches); нг(А), LS, FRLS for group installation.
XLPE insulation allows +90 °C on the conductor versus +70 °C for PVC, so at the same load the cable has a safety margin.

Technical data

Voltage0.66 kV; 1 kV (50 Hz)
Operation−50…+50 °C
Installation without preheatingnot below −15 °C
Bending radius10 D single-core; 7.5 D multi-core
Conductor temperature+90 / +130 / +250 °C *
Test voltage3.5 kV (1 kV)
Service life / warranty30 years / 5 years

* conductor temperature: continuous / overload / short circuit

Conductor cross-sections

ПвВГ

1–5×1,5–240

ПвБШв, ПвБбШв

1×1,5–400
2×1,5–300
3×1,5–300
4×1,5–240
5×1,5–240

number of cores × cross-section, mm²

ПвВГ, ПвБШв, ПвБбШв — ГОСТ 31996-2012 СТ РК IЕС 60502-1-2012

ПвБбШв — ГОСТ 31996-2012

How to write the order

Кабель ПвВГнг(А)-LS 5×10ок(N, PE)-1 ГОСТ 31996-2012

ПвВГнг(А)-LS, 5 conductors of 10 mm², solid round, with neutral and earth conductors, 1 kV

XLPE-insulated

Types: 17 · 1,5–400 mm²

Request a quote

Other catalogue sections