ArmouredArmoured ВБШв, ВБбШв

Armoured power cables with copper conductors, PVC insulation and protective sheath, 0.66 and 1 kV

ГОСТ 31996-2012

  • Бsteel tape armour
  • Ббprofiled tape
  • ШвPVC outer sheath
Request a quote
Armoured ВБШв, ВБбШв
rated voltage
0.66 / 1 kVrated voltage
conductor cross-section
1,5–400 mm²conductor cross-section
number of cores
1–5number of cores
steel tapes
armoursteel tapes
laying in trenches
in the groundlaying in trenches

Types and versions · 15

ВБШвsteel tapes
  • ВБШв

Armour of two galvanised steel tapes, PVC protective sheath

ВБбШвprofiled tape
  • ВБбШв

Armour of profiled steel tape, PVC protective sheath

нг(А)flame retardant
  • ВБШвнг(А)
  • ВБбШвнг(А)

Flame retardant in group installation (category A)

нг(А)-LSlow smoke
  • ВБШвнг(А)-LS
  • ВБбШвнг(А)-LS

Reduced fire hazard, low smoke and gas emission

нг(А)-LSLTxlow toxicity
  • ВБШвнг(А)-LSLTx
  • ВБбШвнг(А)-LSLTx

The same, low toxicity of combustion products

нг(А)-FRLSfire-resistant
  • ВБШвнг(А)-FRLS
  • ВБбШвнг(А)-FRLS

Fire-resistant, with a thermal barrier of mica tapes

нг(А)-FRLSLTxfire-res., low tox.
  • ВБШвнг(А)-FRLSLTx
  • ВБбШвнг(А)-FRLSLTx

Fire-resistant, low toxicity of combustion products

ХЛdown to −60 °C
  • ВБШв-ХЛ
  • ВБШвнг(А)-ХЛ
  • ВБШвнг(А)-LS-ХЛ

Cold-resistant version, operation down to −60 °C

Construction

12345
Schematic cross-section. Core and sheath colours may differ.
  1. Conductorcopper, class 1 or 2 to GOST 22483
  2. InsulationPVC compound; нг(А), LS: reduced fire hazard
  3. Laying uplaid up into a core with belt insulation
  4. Armourgalvanised steel tapes (Б) or profiled steel tape (Бб)
  5. Protective sheathPVC compound

Applications

  • Laying in the ground (trenches), in cable structures and premises where mechanical damage is possible, without significant tensile forces.
  • нг(А), LS, FRLS for group installation inside buildings and in cable structures.
For laying in the ground choose an armoured cable; for group installation inside buildings, the нг(А)-LS and нг(А)-FRLS versions.

Technical data

Voltage0.66 kV; 1 kV (50 Hz)
Climatic versionУХЛ, Т, ХЛ (GOST 15150)
Operation−50…+50 °C (ХЛ: from −60 °C)
Installation without preheatingnot below −15 °C
Bending radius10 D
Conductor temperature+70 / +90 / +160 °C *
Test voltage3 kV (0.66 kV); 3.5 kV (1 kV)
Service life / warranty30 years / 5 years

* conductor temperature: continuous / overload / short circuit; short circuit, sections above 300 mm²: +140 °C

Conductor cross-sections

1×1,5–400
2×1,5–300
3×1,5–300
4×1,5–240
5×1,5–240

number of cores × cross-section, mm²

How to write the order

Кабель ВБШв 4×16ок(N)-0,66 ГОСТ 31996-2012

ВБШв, 4 conductors of 16 mm², solid round, with neutral conductor, 0.66 kV

Armoured ВБШв, ВБбШв

Types: 15 · 1,5–400 mm²

Request a quote